Solution to insufficient suction of woodworking carving machine platform
Source:本站Time:2016/3/9 13:42:31
In the use of woodworking carving machines, there may be a phenomenon of no suction force on the suction table and inability to adsorb the board. What is the reason for this and how should it be solved? Today, we will introduce to you the solution for the non adsorption of the woodworking carving machine table:
1. Is the voltage of the motor circuit normal;
2. Is the water circulation air pump adding too little water, and is the motor stuck or rusted? Remove the motor fan protective net and rotate the axis;
3. Cleaning of filter blockage inside the vacuum pump;
4. Repair any air leakage on the countertop or pipeline;
5. Swap the motor in both forward and reverse directions, and change the direction of the motor with any two wires.
The woodworking carving machine uses vacuum suction to fix the board, which can not only firmly fix it without moving or carving misplacement, but also fix it relative to the clamp plate, saving the board and carving to the edge of the board, saving time and effort.