Problem 1: When opening the software, it prompts: three-axis alarm, initialization error signal. Solution:
1. Check if the fuse of the adapter board in the control box is burnt out and replace the fuse. 2. Check if the two data cables between the computer and the machine are properly connected. 3. Check if the power supply is working properly
Problem 2: When opening the software, the computer prompts "Failed to open the card, please check the card". Solution: 1. Check if the driver program of the board is installed, or replace the board with a PCI slot: 2. Reinstall the two data connection cables and check for any broken pins; 3. There is a problem with the Weihong card. Replace the card
Problem 3: Misalignment or incorrect size during carving. Solution 1: Check if the path of the carving software is correct. 2. Check if the gap size of the screw and the fastening screw of the light rod are loose. 3. Check if the software parameter settings are correct
Problem 4: The spindle motor does not rotate or reverses. Solution: 1. Check the parameter settings of the frequency converter. 2. Check if the signal line of the frequency converter is connected in reverse
Problem 5: When walking on a certain section of the X-axis, the Z-axis does not lift the knife, but moves upwards but downwards. Solution 1: Check if the Z-axis motor is running normally, the power and driver current. 2. Check if the Z-axis motor wire has poor contact or middle breakage. 3. Check if the lifting distance is set properly
Problem 6: The phenomenon of tool smashing occurs. Solution: 1. Insufficient power of the Z-axis motor and loose coupling; 2. The current of the Z-axis driver is too low, or the signal line is connected incorrectly. 3. The data line is not connected properly. Problem 7: When opening the software and starting up, the axis shuts down. Solution: 1. Driver problem or poor contact of the computer output signal line; 2. Poor contact of motor wires
Problem 8: The machine does not power on when turned on. Solution: 1. Check if the start button wire is properly connected and if the button is burnt out. 2. Check if the AC contactor is short circuited or burnt out,
This content mainly summarizes the above eight points about mold carving machines for everyone. We hope that the above content can provide valuable help in everyone's work!
{1}
{2}
{3}
{4}
{5}
{6}
{7}
{8}